Author: n.sene
Type: Publication
Downloaded: 244 times
Date: 2015-10-22
Rating: * 4 vote(s)
10/10


Fault Current Limiters in Industrial Power Systems


Description:
The concept of saturable core fault current limiter (FCL) is relatively known nowadays. It usually consists of two reversely magnetized cores per phase to effectively limit the fault current passively... see more

Tag(s): saturable core fault current limiter (FCL), industrial power system, induction machine, EMTP; fault current analysis, medium voltage
Author: h.gras
Type: Example
Downloaded: 317 times
Date: 2015-06-16
Rating: * 2 vote(s)
5/10


Content of the webinar studies from A to Z on TRV


Description:
Designs built or presented during the webinar of the series Studies from A to Z on Transient Recovery Voltage
Models built:
- Rating TRV envelop (IEC 62271-100 / C37.010 - 2011)
- CP / ... see more

Tag(s): TRV, Transient recovery voltage, short-line fault, terminal fault, substation, 62271, 37.011, lines, switching, thevenin
Author: h.gras
Type: Example
Downloaded: 329 times
Date: 2015-06-16
Rating: * 1 vote(s)
9/10


Content of the webinar studies from A to Z on lightning strokes


Description:
Designs built or presented during the webinar of the series Studies from A to Z on Lightning stroke analysis.
Models built:
- Metal Oxide surge arrester (IEEE working group 3.4.11)
- To... see more

Tag(s): Lightning, stroke, fast-front transient, tower, arrester, cigre, line, substation, parametric, corona, air-gap, leader
Author: n.sene
Type: Publication
Downloaded: 266 times
Date: 2015-04-02
Rating: * 0 vote(s)
0/10


Short-Term Scheduling of Active Distribution Systems


Description:
The latest distribution management systems tend to incorporate optimization functions for the short-term scheduling of the various energy and control resources available in the network (e.g., embedded... see more

Tag(s): Distributed generation, operation of distribution networks, MILP.
Author: n.sene
Type: Publication
Downloaded: 266 times
Date: 2015-04-02
Rating: * 1 vote(s)
5/10


Indirect Lightning Performance of a Real Distribution Network with focus on Transformer Protection


Description:
The paper applies the Monte Carlo procedure proposed by the Authors to evaluate the indirect lightning performance of a real medium-voltage distribution network, which includes feeders and laterals, p... see more

Tag(s): induced voltages; distribution networks; Monte Car lo method; lightning protection; MTBF.