Exchange Platform

Welcome to the exchange platform.

To download and share your file(s), please login :


6 Results for the search " external":

Author: h.gras
Type: Example
Downloaded: 92 times
Date: 2018-01-02
Rating: * 0 vote(s)
0/10


Change load power from an external file


Description:
This example illustrates how to read data from an external file and automatically update devices parameters in the design. In this example, the device is a load.
Double click on Update Parameters... see more

Tag(s): script, parametric, file, external, automate, Load
Author: n.sene
Type: Publication
Downloaded: 266 times
Date: 2015-04-02
Rating: * 0 vote(s)
0/10


Power system islands, autonomous microgrids and relevant instrumentation


Description:
Unplanned power system islanding is usually seen as a major risky operating condition and specific countermeasures are applied in order to avoid it. However the capability of voluntary disconnection f... see more

Tag(s): Power systems islanding, microgrids, measurements.
Author: n.sene
Type: Publication
Downloaded: 275 times
Date: 2015-04-01
Rating: * 0 vote(s)
0/10


Analysis of black-startup and islanding capabilities of a combined cycle power plant


Description:
The paper presents the analysis of black-startup and islanding capabilities of an 80 MW combined cycle power plant. The analysis is carried out by means of a computer dynamic simulator suitably develo... see more

Tag(s): black-startup, islanding, combined cycle, power plant, energization
Author: gerinlajoie.luc
Type: Model
Downloaded: 140 times
Date: 2012-11-23
Rating: * 3 vote(s)
9/10


Extra control functions


Description:
Extra control functions, 17 components: Dead band, Friction, QuantizerLess than (for T1 duration and reset at 110% of the level)
- useful for analogical inputLess than (for T1 duration and reset... see more

Tag(s): Components
Author: AdminEMTP-RV
Type: Document
Downloaded: 554 times
Date: 2012-06-18
Rating: * 2 vote(s)
4/10


Look what happens without EMTP-RV


Description:
This is a nice video about the switching of a shunt reactor (most probably 500 kV) with a Circuit-Switcher.
>A circuit-switcher is a SF6 load-break swith with no fault current breaking capabil... see more

Tag(s):
Author: AdminEMTP-RV
Type: Document
Downloaded: 254 times
Date: 2012-06-18
Rating: * 0 vote(s)
0/10


Presentation of an approach based on EMTP for the calculation of lightning induced overvoltages


Description:
Authors:
A. Xémard, P. Baraton, B. Bressac, N. Qako, J. Mahseredjian, G. Simard, J. Ribeiro, R. Tarafi, A. Zeddam.

Abstract:
LIPS (Lightning Impact on Power Systems) is a toolbo... see more

Tag(s):